Every electric circuit should be protected against overcurrent. Fuses are the most frequently used solutions. Understanding how they work simplifies choosing the optimal fuse for the application.
This is an archive article published 09/19/2018. Some information may no longer be up to date and in line with the current state. Please contact us in case of interest.

How Fuse Works

Fuse contains a metallic element which is heated to its melting point by the excessive current. The element is designed in such a way that it melts within defined times for various overcurrent values.
Once the element melts open, the circuit voltage across the two ends of the open element creates arc. The fuse is designed so that the arc burns only inside it and it is extinguished without damaging the fuse housing (glass/ceramic tube, plastic case, etc.). The arc is extinguished when the element ends burn back far enough that the arc cannot be maintained across the increasing gap.
Some fuses employ a “filler”, typically silica sand to help disrupt and extinguish the arc.


obr2207_p733439176867.jpg


What to Consider?

Rated Current, In

  1. For fuse, according to EC 60127 and EN 60127, the rated current corresponds to the continuous current through the fuse without interrupting the fuse.
  2. For fuse, according to UL 248-14, the rated current corresponds to the current, which would interrupt the fuse-link already after a few hours. The current which, according to UL, can flow constantly without interrupting the fuse-link, is approx. 0.75 In.


Voltage rating (AC or DC voltage)
The voltage rating of the fuse must be equal to, or greater than, the circuit voltage. If circuit voltage is considerably lower than fuse rated voltage, voltage drop on fuse has to be taken into account. When metal element approaches melting point, voltage drop increases.
The circuit voltage must be sufficient to allow current that is capable of interrupting the element.


Ambient temperature
Fuse current ratings are measured at 23°C (IEC) or 25°C (UL). In practical applications, the fuse’s ambient temperature may be significantly higher, especially if the fuse is used in an unexposed fuseholder or mounted near other heat generating components. For such applications, In has to be de-rated according to manufacturer recommendation.

obr2207_pbe8117525f63.jpg


Overload current and opening time
The time-current-characteristic indicates the relation between the time required to melt the element (pre-arcing time) and the current.

obr2207_p0d0782cb9f49.jpg



Actual time-current characteristic is between Imin and Imax curves.


obr2207_p98ed3aaed27e.jpg



obr2207_pe11df0527b5e.jpg


Breaking Capacity
A fuse must be able to open the circuit under a short circuit condition without endangering its surroundings. The fuse breaking capacity is defined as the maximum current at rated voltage, which the device can safely open without rupturing. It must be equal to or greater than the available short circuit current of the circuit.
Breaking capacity for 5x20mm fuse is typically 35A or 10xIn depending on which current is greater.


Inrush Currents
Every AC/DC converter charges capacitor behind the bridge rectifier when switched ON. Fuse has to withstand inrush current without interrupting the circuit. To fulfil this condition, fuse i2t rating has to be greater than measured inrush current i2t.

obr2207_p66b98db557f0.jpg


In addition, fuse has to withstand inrush currents during the whole lifetime of the device. In such a case it is necessary to use the fuse with higher i2t rating.

Application example
Let the measured inrush current has the same shape as on the picture above. Power supply will be switched on twice a day, 240 days in year, expected lifetime is 10 years.
Design uses time-lag fuse.
Ip=13A, τ=5ms then i2t=0.5*13^2*0.005=0.422A2s.

obr2207_p77d3d9a656bb.jpg


Power supply will be switched ON 4 800 times. The graph shows that the calculated i2t corresponds to only 30% of the required i2t. Required i2treq = i2t/F=1,407 A2s.

Fuse in Fuseholder
5x20mm fuses are very often placed in fuseholder. Current flowing through the fuse and the contact resistance between the fuse and fuseholder creates power dissipation. Fuseholder power acceptance at given ambient temperature has to be higher than created power dissipation.

Testing in application and verification prior to production
The factors presented here should be considered in selecting the fuse for the given application. The next step is to verify fuse performance under normal conditions and overload tests under fault conditions to ensure that the fuse will operate properly in the circuit.

If you're interested in this topic, please check out the fuses overview on our websites.


Do not miss these articles

Do you like our articles? Do not miss any of them! You do not have to worry about anything, we will arrange delivery to you.

Additional products


5HF 800-R BEL FUSE  
5HF 800-R

Ceramic Body Cartridge Fuse 5x20mm Fast-Acting F 800mA 250VAC

Cartridge Fuses

Ord. No.: 75323
Manufacturer: BEL FUSE
in stock 1870 pcs
10 pcs+
0,0778 €
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare

6,3x32 T 15A (202.000 15A) PÜSCHEL  
6,3x32 T 15A (202.000 15A)

Glass Body Cartridge Fuse 6,3x32mm Slow-Acting T 15A 250VAC

Cartridge Fuses

Ord. No.: 16916
Manufacturer: PÜSCHEL
No longer available

0034.6005 SCHURTER  
0034.6005

Thermoplastic Body PCB Radial Fuse MSF 250 Fast-Acting F 125mA 250VAC 8,5x8,5mm, Short Terminal

PCB Fuses

Ord. No.: 63692
Manufacturer: SCHURTER
in stock 150 pcs
5 pcs+
10 pcs+
100 pcs+
300 pcs+
1000 pcs+
0,4330 €
0,3950 €
0,3340 €
0,3140 €
0,3020 €
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare

0034.6006 SCHURTER  
0034.6006

Thermoplastic Body PCB Radial Fuse MSF 250 Fast-Acting F 160mA 250VAC 8,5x8,5mm, Short Terminal

PCB Fuses

Ord. No.: 63693
Manufacturer: SCHURTER
in stock 700 pcs
5 pcs+
10 pcs+
100 pcs+
300 pcs+
1300 pcs+
0,3980 €
0,3230 €
0,2780 €
0,2610 €
0,2380 €
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare

0034.6009 SCHURTER  
0034.6009

Thermoplastic Body PCB Radial Fuse MSF 250 Fast-Acting F 315mA 250VAC 8,5x8,5mm, Short Terminal

PCB Fuses

Ord. No.: 63695
Manufacturer: SCHURTER
in stock 16 pcs
5 pcs+
10 pcs+
100 pcs+
300 pcs+
1100 pcs+
0,3980 €
0,3610 €
0,3050 €
0,2920 €
0,2740 €
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare

0034.6013 SCHURTER  
0034.6013

Thermoplastic Body PCB Radial Fuse MSF 250 Fast-Acting F 800mA 250VAC 8,5x8,5mm, Short Terminal

PCB Fuses

Ord. No.: 63698
Manufacturer: SCHURTER
in stock 1900 pcs
5 pcs+
10 pcs+
100 pcs+
300 pcs+
1200 pcs+
0,3980 €
0,3510 €
0,2970 €
0,2840 €
0,2600 €
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare

0034.6015 SCHURTER  
0034.6015

Thermoplastic Body PCB Radial Fuse MSF 250 Fast-Acting F 1,25A 250VAC 8,5x8,5mm, Short Terminal

PCB Fuses

Ord. No.: 63700
Manufacturer: SCHURTER
in stock 910 pcs
5 pcs+
10 pcs+
100 pcs+
300 pcs+
1000 pcs+
0,4260 €
0,3880 €
0,3290 €
0,3090 €
0,2970 €
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Do you agree with cookies being stored?
Welcome to the SOS electronic website. Before you enter our online world, we would like to ask you to allow us to store cookies on your browser. Your consent will help us view the site without error, measure its performance, and track additional statistics. Apart from that, we can bring you an offer of our products and services, literally tailor-made. We also provide cookies to third parties. However, you are definitely safe with us.
The proper operation of the website
More stable technical control
Better marketing offer

More about cookies
More about personal data processing

Necessary Only selected Accept all cookies