Verfügbare filter
Verfügbare filter
|
Hersteller
NISSHA FIS
|
- | 0,6-1,2 | D7,6 x 8,4 mm | - | Hydrogen (H2) | 10...2 000ppm | - | - | ΔR | Sensor | -10...+60°C | - | MOS | - mA | - | Pins for socket | - | - |
|
Hersteller
NISSHA FIS
|
- | - | D13,4 x 7,6 mm | - | Refrigerants (R410a, R407c, R134a) | 10...1 000ppm | - | - | ΔR | Sensor | -10...+60°C | - | MOS | - mA | - | Pins for socket | - | - |
|
Hersteller
NISSHA FIS
|
- | 0,4-0,7 | D20 x 10 mm | - | Refrigerants ( R410A, R407C, R32, HFO1234yf) | 600...3 000ppm | - | - | ΔR | Sensor | -10...+50°C | - | MOS | - mA | - | Pins for socket | - | - |
|
Hersteller
NISSHA FIS
|
- | 1,05-2,1 at 30-100ppm | D20 x 10 mm | - | Carbon monoxide (CO) | 30...500ppm | - | - | ΔR | Sensor | -10...+60°C | - | MOS | - mA | - | Pins for socket | - | - |
|
Hersteller
NISSHA FIS
|
- | - | D13,4 x 7,6 mm | - | Ammonia (NH3) | 0,1...100ppm | - | - | ΔR | Sensor | -10...+50°C | - | MOS | - mA | - | Pins for socket | - | - |
|
Hersteller
NISSHA FIS
|
- | 1,05-2,1 at 30-100ppm | D20 x 10 mm | - | Carbon monoxide (CO), Methane (CH4) | CH4: 300...7 000ppm, CO: 30...700ppm | - | - | ΔR | Sensor | -10...+60°C | - | MOS | - mA | - | Pins for socket | - | - |
|
Hersteller
SENSIRION
|
- | - | 35 x 23 x 7 mm | CO2 output range: 0...40 000ppm I2C, UART, 0...5 000ppm PWM | Carbon dioxide (CO2) | 0...40 000ppm at I2C, UART, 0...5 00ppm at PWM | - | - | UART/I2C, PWM | Module | 0...+50°C | 3,3...5,5V | NDIR | 19 (Avg. Typ.) mA | ±(30 ppm + 3%) at 400...10 000ppm | SMD | RH and T measurement | - |
|
Hersteller
SENSIRION
|
SCD4x | - | 10,1 x 10,1 x 6,3 mm | *1: low power mode | Carbon dioxide (CO2) | 0...40 000ppm | - | - | I2C | Sensor | -10...+60°C | 2,4...5,5V | NDIR | 15mA, 3,2mA *1 (Typ., Avg.) @ 3,3V mA | ±(50 ppm + 5 %) at 400...2 000ppm | SMD | RH and T measurement, low power mode | 1 |
|
Hersteller
SENSIRION
|
SCD4x | - | 10,1 x 10,1 x 6,3 mm | *1: low power mode | Carbon dioxide (CO2) | 0...40 000ppm | - | - | I2C | Sensor | -10...+60°C | 2,4...5,5V | NDIR | 15mA, 3,2mA *1 (Typ., Avg.) @ 3,3V mA | ±(50 ppm + 5 %) at 400...2 000ppm | SMD | RH and T measurement, low power mode | 1 |
|
Hersteller
SENSIRION
|
SCD4x | - | 10,1 x 10,1 x 6,3 mm | *1: low power mode, *2: single shot mode | Carbon dioxide (CO2) | 0...40 000ppm | - | - | I2C | Sensor | -10...+60°C | 2,4...5,5V | NDIR | 15mA, 3,2mA *1, 0,45mA *2 (Typ., Avg.) @ 3,3V mA | ±(50 ppm + 3 %) at 400...2 000ppm | SMD | RH and T meas., low power mode, single shot mode | 1 |
|
Hersteller
SENSIRION
|
SCD4x | - | 10,1 x 10,1 x 6,3 mm | *1: low power mode, *2: sinngle shot mode | Carbon dioxide (CO2) | 0...40 000ppm | - | - | I2C | Sensor | -10...+60°C | 2,4...5,5V | NDIR | 15mA, 3,2mA *1, 0,45mA *2 (Typ., Avg.) @ 3,3V mA | ±(50 ppm + 3 %) at 400...2 000ppm | SMD | RH and T meas., low power mode, single shot mode | 1 |
|
Hersteller
SENSIRION
|
SCD4x | - | 10,1 x 10,1 x 6,3 mm | *1: low power mode, *2: sinngle shot mode | Carbon dioxide (CO2) | 0...40 000ppm | - | - | I2C | Sensor | -10...+60°C | 2,4...5,5V | NDIR | 15mA, 3,2mA *1, 0,45mA *2 (Typ., Avg.) @ 3,3V mA mA | ±(30 ppm + 3 %) at 400...5 000ppm | SMD | RH and T meas., low power mode, single shot mode | 1 |
|
Hersteller
SENSIRION
|
SGD4x | - | 90 x 55 x 24 mm | LFL: lower flammability limit | R-32 and R-454B in Air | - | 11% LFL (R32), 12% LFL (R-454B) | NO contact x2 | RS-485/MODBUS | Module | -40...+85°C | 24 VDC ±10%, 18...30 VAC RMS | Thermal Conductivity | 70 mA Typ. @ DC, 120 mA RMS Typ. @ AC mA | ±2.5 %LFL | 8-pin sealable connector, mating part TE 794821-1 | Refrigerant sensor: UL 60335-2-40, refrigerant detection: UL 60335-2-89 | - |
|
Hersteller
SENSIRION
|
SGD4x | - | 90 x 55 x 24 mm | LFL: lower flammability limit | R-454A, R-454C and R-455A in Air | - | 14% LFL (R-454A, C), 10% LFL (R-455A) | NO contact x2 | RS-485/MODBUS | Module | -40...+85°C | 24 VDC ±10%, 18...30 VAC RMS | Thermal Conductivity | 70 mA Typ. @ DC, 120 mA RMS Typ. @ AC mA | ±2.5 %LFL | 8-pin sealable connector, mating part TE 794821-1 | Refrigerant sensor: UL 60335-2-40, refrigerant detection: UL 60335-2-89 | - |
|
Hersteller
SENSIRION
|
SGP4x | 870 at 5-10ppm | 2,44 x 2,44 x 0,85 mm | MCU that runs Sensirion VOC algorithm is required. | Volatile organic compound (VOC) | 0...1000 ppm ethanol equiv | - | - | I2C | Sensor | -10...+50°C | 1,7...3,6V | MOS | 2,6mA (Typ) @ 3,3V mA | - | Connector | VOC Index 1...500 | 1 |
|
Hersteller
SENSIRION
|
SGP4x | - | 2,44 x 2,44 x 0,85 mm | MCU that runs Sensirion VOC algorithm is required. | Volatile Organic Compound (VOC), NOx | 0...1000 ppm ethanol equiv, 0...10 ppm NO2 equiv | - | - | I2C | Sensor | -10...+50°C | 1,7...3,6V | MOS | 3,2mA (Typ) @ 3,3V mA | - | SMD | VOC Index 1...500, NOx Index 1...500 | - |
|
Hersteller
SGX SENSORTECH
|
4 series | 4,8 ± 1,4 uA/% O2 | D20 x 16,5 mm | Maximum overload: 30% O2 | Oxygen (O2) | 0...25% | - | - | Current | Sensor | -40...+60°C | - | Electrochemical | - mA | - | Pins for socket | - | - |
|
Hersteller
SGX SENSORTECH
|
- | - | 39 x 35 x 27 mm | - | H2 in Air | 0...10% | - | - | CAN | Module | -40...+85°C | 9...18V | Thermal Conductivity | 25mA @12 V mA | ± 0,4 vol @ H2 in air ≤ 4% vol, H2 in air ≥ 4% vol ± 10% MV | Connector | IP6K7 | - |
|
Hersteller
SGX SENSORTECH
|
- | - | 39 x 35 x 27 mm | - | H2 in air, CO | 0...4% H2 | - | - | CAN | Module | -40...+85°C | 9...18V | Thermal Conductivity (H2), MOS (CO) | 50 mA (max.) @ 12V mA | ± 0,4% @ (Temp 0...25°C, RH 10...95%) | Connector | IP6K7 | - |
|
Hersteller
SGX SENSORTECH
|
- | 0,6 mV/% O2, typ. | D29,3 x 38,2 mm | Expected operating lifetime: 8,7 years at 21% O2 | Oxygen (O2) | 0...100% | - | - | Voltage | Sensor | -20...+50°C | - | Electrochemical | - mA | - | Connector | - | - |
|
Hersteller
SGX SENSORTECH
|
4 series | 45 ± 15 nA/ppm | D20 x 16,5 mm | - | Carbon monoxide (CO) | 0...1000ppm | - | - | Current | Sensor | -20...+50°C | - | Electrochemical | - mA | - | Pins for socket | - | - |
|
Hersteller
NISSHA FIS
|
- | - | D18 x 14 mm | - | Ozone (O3) | 10...250ppb | - | - | ΔR | Sensor | -10...+50°C | - | MOS | - mA | - | Pins for socket | - | - |
|
Hersteller
SENSIRION
|
STC | 16 bit / 30,5 ppm | 3,5 x 3 x 1 mm | - | CO2 in N2 and CO2 in air | 0...40%, 0...100% | - | - | I2C | Sensor | -20...+85°C | 2,7...5,5V | Thermal Conductivity | 3 (Typ) mA | ± (0,2% + 0,02% * ΔC + 0,02% * ΔT + 0,01% * ΔRH + 0,001 * ΔP) | SMD | - | 1 |
|
Hersteller
SENSIRION
|
- | 1 ppm (Typ.) | 4 x 3 x 1,2 mm | Requires SHT4x for RH&T compensation | CO2 in N2 and CO2 in air | 380...32 000 ppm | - | - | I2C | Thermal Conductivity | 10...40°C | 2,7...5,5 V | Thermal Conductivity | 0,95 mA (Typ., continuous meas. mode) mA | ±(100ppm+10% MV) @ 400...5 000 ppm | SMD | Automatic Self-Calibration | 1 |
|
Hersteller
FIGARO
|
- | 0,3-0,6 | D17,8 x 9,2 mm | - | Air contaminants | 1...100ppm | - | - | ΔR | Sensor | -10...+50°C | - | MOS | - mA | - | Solid legs | - | - |