Filtres disponibles
Filtres disponibles
|
Fabricant
FIGARO
|
- | 0,52-0,65 | D22,4 x 9,2 mm | - | Methane (CH4) | 300...10 000ppm | - | - | ΔR | Sensor | -40...+70°C | - | MOS | - mA | - | Solid legs | - | - |
|
Fabricant
FIGARO
|
- | - | D49 x 20,9 mm | - | Carbon monoxide (CO) | 0...10 000ppm | - | - | Current | Sensor | 0...+50°C | - | Electrochemical | - mA | - | - | Battery operable electrochemical sensor | - |
|
Fabricant
FIGARO
|
- | - | D10,8 x 13,9 mm | - | Carbon monoxide (CO) | 0...5 000ppm | - | - | Current | Sensor | -10...+50°C | - | Electrochemical | - mA | - | Solid legs | Battery operable electrochemical sensor | - |
|
Fabricant
FIGARO
|
- | - | 3,2 x 2,5 x 0,99 mm | - | Air contaminants | 1...100ppm | - | - | ΔR | Sensor | -10...+50°C | - | MOS | - mA | - | SMD | - | - |
|
Fabricant
FIGARO
|
- | - | D16,5 x 17 mm | - | Combustible gases (Methane, Propane, Iso-butane) | 500...10 000ppm | - | - | ΔR | Sensor | -40...+70°C | - | MOS | - mA | - | Solid legs | - | - |
|
Fabricant
FIGARO
|
- | - | D16,5 x 17 mm | - | Organic solvent vapors, ethanol | 50...5 000ppm | - | - | ΔR | Sensor | -10...+40°C | - | MOS | - mA | - | Solid legs | - | - |
|
Fabricant
SGX SENSORTECH
|
- | - | 39 x 35 x 27 mm | - | - | - | - | - | LIN 2.1 | Module | -40...+85°C | 9...15V | Thermal Conductivity (H2), MOS (CO, NH3) | 80mA (max) @ 12V mA | ± 0,4% @ (Temp 0...25°C, RH 10...95%) | Connector | IP6K7, pressure measurement 20...250 kPa over the air pressure | - |
|
Fabricant
SGX SENSORTECH
|
VQ500 | 4mV/% CH4, Min. | D20 x 16,5 mm | *1: x depends on gas | Mixture of known gas and air | x…100% *1 | - | Voltage | ΔR | Sensor | -40...+55°C | 4,25V | Thermal Conductivity | 50...60 mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | MSL 1 |
|
Fabricant
SGX SENSORTECH
|
VQ500 | 21 mV/% NH3, Min. | D20 x 16,5 mm | - | Ammonia (NH3) | 0...15% | - | Voltage | ΔR | Sensor | -40...+55°C | 3V | Catalytic | 40...50mA mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | MSL 1 |
|
Fabricant
SGX SENSORTECH
|
VQ500 | 30 mV/% CH4, Min. | D20 x 16,5 mm | Poison and shock resistant | Combustible gases | 0...5% CH4 | - | Voltage | ΔR | Sensor | -40...+55°C | 4,25V | Catalytic | 50...60 mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | MSL 1 |
|
Fabricant
SGX SENSORTECH
|
- | - | - | - | - | - | - | - | - | Accessory | - | - | - | - mA | - | - | - | MSL 1 |
|
Fabricant
NISSHA FIS
|
- | - | D13,4 x 7,6 mm | - | Hydrogen sulfide (H2S) | 3...1 000ppm | - | - | ΔR | Sensor | -10...+50°C | - | MOS | - mA | - | Pins for socket | - | - |
|
Fabricant
SGX SENSORTECH
|
- | - | - | - | - | - | - | - | - | Accessory | - | - | - | - mA | - | - | - | - |
|
Fabricant
SGX SENSORTECH
|
- | - | - | - | - | - | - | - | - | Accessory | - | - | - | - mA | - | - | - | - |
|
Fabricant
SGX SENSORTECH
|
- | - | - | - | - | - | - | - | - | Accessory | - | - | - | - mA | - | - | - | MSL 1 |
|
Fabricant
SGX SENSORTECH
|
4 series | 20 ± 8 nA/ppm | D20 x 16,6 mm | - | Sulfur dioxide (SO2) | 0...2000ppm | - | - | Current | Sensor | -20...+50°C | - | Electrochemical | - mA | - | Pins for socket | - | - |
|
Fabricant
SGX SENSORTECH
|
INIR | - | D20 x 16,6 mm | *1: Whichever error is larger | Butane (C4H10) | 0...1,8% | - | - | UART, Voltage 1,25…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb | - |
|
Fabricant
SGX SENSORTECH
|
INIR | - | D20 x 16,6 mm | *1: Whichever error is larger | Carbon dioxide (CO2) | 0...5% | - | - | UART, Voltage 0…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb | MSL 1 |
|
Fabricant
SGX SENSORTECH
|
INIR | - | D20 x 16,6 mm | *1: Whichever error is larger | Methane (CH4) | 0...5% | - | - | UART, Voltage 1,25…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb | MSL 1 |
|
Fabricant
SGX SENSORTECH
|
INIR | - | D20 x 16,6 mm | *1: Whichever error is larger | Methane (CH4) | 0...100% | - | - | UART, Voltage 1,25…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb | MSL 1 |
|
Fabricant
SGX SENSORTECH
|
INIR | - | D20 x 16,6 mm | *1: Whichever error is larger | Propane (C3H8) | 0...2,1% | - | - | UART, Voltage 1,25…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb | MSL 1 |
|
Fabricant
SGX SENSORTECH
|
INIR | - | D20 x 16,6 mm | *1: Whichever error is larger | Refrigerants (R290) | 0...2,1% | - | - | UART, Voltage 1,25…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb | MSL 2 |
|
Fabricant
SGX SENSORTECH
|
INIR | - | D20 x 16,6 mm | *1: Whichever error is larger | Refrigerants (R32) | 0...14% | - | - | UART, Voltage 1,25…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb | MSL 2 |
|
Fabricant
SGX SENSORTECH
|
INIR | - | D20 x 16,6 mm | *1: Whichever error is larger | Refrigerants (R600) | 0...1,8% | - | - | UART, Voltage 1,25…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb | - |
|
Fabricant
SGX SENSORTECH
|
INIR4 | ± 0,005% FS | 39,7 x 19,8 x 10,7 mm | *1: Whichever error is larger , Do not solder sensor pins | Refrigerants (R290) | 0...2,1% | 0,42% (20% LEL), SW configurable | TTL Levels | UART, PWM (100Hz, duty cycle 10...90%) | Sensor | -20...+60°C | 3,2...5,25V | NDIR | 32 mA (Typ) @ 5 V mA | ±10% or 0,1% FS, *1 | Pins for socket | Meets UL 60335-2-40 / IEC 60079-29-1 / IEC60335-2-40 | - |