Available filters
Available filters
|
Manufacturer
SGX SENSORTECH
|
INIR4 | ± 0,005% FS | 39,7 x 19,8 x 10,7 mm | *1: Whichever error is larger , Do not solder sensor pins | Refrigerants (R32) | 0...7% | 2,8% (20% LEL) | TTL Levels | UART, PWM (100Hz, duty cycle 10...90%) | Sensor | -20...+60°C | 3,2...5,25V | NDIR | 32 mA (Typ) @ 5 V mA | ±10% or 0,1% FS, *1 | Pins for socket | Atex: II 1G Ex ia IIB T4 Ga, IECEx: Ex ia IIB T4 Ga, dual channel | - |
|
Manufacturer
SGX SENSORTECH
|
INIR7 | 50 ppm | Module 67 x 76 x 20,5 mm | *1: Whichever error is larger, basic error | Refrigerants (R290) | 0.02...2,1% | 0,42%, SW configurable | Alarm ON: V_supply, Alarm OFF: high impedance | Modbus RS-485 | Module | -40...+75°C | 24 VDC Typ. 4,5...30 VDC | NDIR | 15 mA @ 24 V mA | ±6% or ±600pmm *1 | Connector | UL 60335-2-40 / IEC 60079-29-1 / IEC60335-2-40, IP65 | - |
|
Manufacturer
SGX SENSORTECH
|
INIR7 | 50 ppm | Module 67 x 76 x 20,5 mm | *1: Whichever error is larger, basic error | Refrigerants (R290) | 0.02...2,1% | 0,42%, SW configurable | Alarm ON: V_supply, Alarm OFF: high impedance | Modbus UART 5V | Module | -40...+75°C | 24 VDC Typ. 4,5...30 VDC | NDIR | 15 mA @ 24 V mA | ±6% or ±600pmm *1 | Connector | UL 60335-2-40 / IEC 60079-29-1 / IEC60335-2-40, IP65 | - |
|
Manufacturer
SGX SENSORTECH
|
IR1 | - | D20 x 19 mm | - | Carbon dioxide (CO2) | 0…5% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR1 | - | D20 x 19 mm | - | Carbon dioxide (CO2) | 0...100% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR1 | - | D20 x 19 mm | - | Carbon dioxide (CO2) | 0...5% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR1 | - | D20 x 16,9 mm | - | Carbon dioxide (CO2) | 0...5% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR1 | - | D20 x 19 mm | - | Carbon dioxide (CO2) | 0...5% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR1 | - | D20 x 16,9 mm | - | Carbon dioxide (CO2) | 0...5% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR1 | - | D20 x 19 mm | - | Hydrocarbons | 0...100% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR1 | - | D20 x 19 mm | - | Hydrocarbons | 0...100% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR1 | - | D20 x 16,9 mm | - | Hydrocarbons | 0...100% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR1 | - | D20 x 19 mm | - | Hydrocarbons | 0...100% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR1 | - | D20 x 16,9 mm | - | Hydrocarbons | 0...100% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR1 | - | D20 x 19 mm | - | Hydrocarbons | 0...100% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR15 | - | D20 x 19 mm | - | Carbon dioxide (CO2), hydrocarbons | 0...5% CO2, 0...100% HC | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR15 | - | D20 x 19 mm | - | Hydrocarbons | 0...100% | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | - |
|
Manufacturer
SGX SENSORTECH
|
IR15 | - | D20 x 19 mm | - | Carbon dioxide (CO2), hydrocarbons | 0...5% CO2, 0...100% HC | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR15 | - | D20 x 19 mm | - | Carbon dioxide (CO2), hydrocarbons | 0...100% CO2, 0...100% HC | - | - | ΔV | Sensor | -20...+55°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR2 | - | D20 x 19 mm | Mining applications | Carbon dioxide (CO2) | 0...5% | - | - | ΔV | Sensor | -20...+60°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: I M1 Ex ia I Ma, IECEx: Ex ia I Ma, dual channel | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR2 | - | D20 x 19 mm | Mining applications | Carbon dioxide (CO2) | 0...5% | - | - | ΔV | Sensor | -20...+60°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: I M1 Ex ia I Ma, IECEx: Ex ia I Ma, dual channel, temp | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR2 | - | D20 x 16,9 mm | Mining applications | Carbon dioxide (CO2) | 0...5% | - | - | ΔV | Sensor | -20...+60°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: I M1 Ex ia I Ma, IECEx: Ex ia I Ma, dual channel, temp | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR2 | - | D20 x 19 mm | Mining applications | Carbon dioxide (CO2) | 0...5% | - | - | ΔV | Sensor | -20...+60°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: I M1 Ex ia I Ma, IECEx: Ex ia I Ma, dual channel, temp | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR2 | - | D20 x 16,9 mm | Mining applications | Carbon dioxide (CO2) | 0...5% | - | - | ΔV | Sensor | -20...+60°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: I M1 Ex ia I Ma, IECEx: Ex ia I Ma, dual channel, temp | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
IR2 | - | D20 x 19 mm | Mining applications | Hydrocarbons | 0...100% | - | - | ΔV | Sensor | -20...+60°C | 3...5V | NDIR | 96mA @ 5V, Typ. mA | - | Pins for socket | ATEX: I M1 Ex ia I Ma, IECEx: Ex ia I Ma, dual channel | MSL 1 |