Dostępne filtry
Dostępne filtry
|
Producent
SGX SENSORTECH
|
- | - | 39 x 35 x 27 mm | - | H2 in Air | 0...4% | - | - | CAN | Module | -40...+85°C | 9...36V | Thermal Conductivity | 28mA @24 V mA mA | ± 0.4% H2 @ 23°C < 10%RH | Connector | IP6K7 | - |
|
Producent
NISSHA FIS
|
FIS5084 | - | 26 x 26 x 20 mm | *1: If the concentration is > 10,000 ppm, VOUT2 will be permanently locked in alarm state | Refrigerants (R32) | 300...10 000 ppm *1 | R32: 5 000ppm ±20% | PWM : Duty cycle=60%, f=2,67 Hz | UART | Module | -25...+60°C | 5V | MOS | 40 mA | Accuracy of gas concentration output is not guaranteed | Connector, BH06B-PASK-1 | SB-43A Sensor, Malfunction output | - |
|
Producent
NISSHA FIS
|
A1320301-SP61 | - | 51 x 37 x 22 mm | Accuracy of gas concentration output is not guaranteed | Ozone (O3) | 20...250ppb | 80ppb ±30ppb | CMOS 5V | Voltage, 0...5V (+0, -10%) | Module | 0...+40°C | 5V ±4% | MOS | 140 mA | - | Connector | SP-61-00 sensor | - |
|
Producent
FIGARO
|
- | - | 32 x 17 x 8 mm | *1: long term accuracy not included | Carbon dioxide (CO2) | 360...5 000ppm | 1 000ppm, user changable | CMOS Output | I2C/UART, PWM | Module | 0...+50°C | 3,3 ± 0,3V or 5 ± 0,5V | NDIR | 25mA @ 5V mA | ±{50ppm + 3% m.v.) *1 | PCB Pins | Dual wavelength system | - |
|
Producent
NISSHA FIS
|
FIS3000 | - | 28 x 41 x 20 mm | Accuracy of gas concentration output is not guaranteed | Methane (CH4) | - | 3 000ppm, 5 000ppm | CMOS 5V x2 | UART | Module | -10...+50°C | 5V | MOS | - mA | - | Connector | SB-12A-00 Sensor, Malfunction output | - |
|
Producent
SGX SENSORTECH
|
INIR2 | ±500ppm @ 5...40% | D20 x 16,6 mm | *1: Whichever error is larger | Carbon dioxide (CO2) | 0...100% | - | - | UART, Voltage 0…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or ±1500ppm, *1 | Pins for socket | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | MSL 1 |
|
Producent
SGX SENSORTECH
|
INIR2 | ±40ppm @ 0...2% | D20 x 16,6 mm | *1: Whichever error is larger | Carbon dioxide (CO2) | 0...5% | - | - | UART, Voltage 0…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or ±60ppm *1 | Pins for socket | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | MSL 1 |
|
Producent
SGX SENSORTECH
|
INIR2 | - | D20 x 16,6 mm | *1: Whichever error is larger | Methane (CH4) | 0...100% | - | - | UART, Voltage 0…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | MSL 1 |
|
Producent
SGX SENSORTECH
|
INIR2 | - | D20 x 16,6 mm | *1: Whichever error is larger | Methane (CH4) | 0...5% | - | - | UART, Voltage 0…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | MSL 1 |
|
Producent
SGX SENSORTECH
|
INIR2 | - | D20 x 16,6 mm | *1: Whichever error is larger | Propane (C3H8) | 0...2,1% | - | - | UART, Voltage 0…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | MSL 1 |
|
Producent
SGX SENSORTECH
|
INIR7 | 50 ppm | Module 67 x 76 x 20,5 mm | *1: Whichever error is larger, basic error | Refrigerants (R290) | 0.02...2,1% | 0,42%, SW configurable | Alarm ON: V_supply, Alarm OFF: high impedance | CAN 2.0 | Module | -40...+75°C | 24 VDC Typ. 4,5...30 VDC | NDIR | 15 mA @ 24 V mA | ±6% or ±600pmm *1 | Connector | UL 60335-2-40 / IEC 60079-29-1 / IEC60335-2-40, IP65 | - |
|
Producent
FIGARO
|
KE-LF | 0,6 mV/% O2, typ. | D23 x 50 mm | *1: When calibrated at both 0% and 30% O2 | Oxygen (O2) | 0...30% | - | - | Voltage | Sensor | +5...+40°C | - | Electrochemical | - mA | ±1% FS *1 | Free wires | Lead-Free, Response time (90%): approx 15 sec. | - |
|
Producent
FIGARO
|
KE-LF | 0,31 mV/% O2, typ. | D23 x 50 mm | *1: When calibrated at both 0% and 100% O2 | Oxygen (O2) | 0...100% | - | - | Voltage | Sensor | +5...+40°C | - | Electrochemical | - mA | ±1% FS *1 | Free wires | Lead-Free, Response time (90%): approx 15 sec. | - |
|
Producent
FIGARO
|
KE-LF | 0,6 mV/% O2, typ. | D28 x 47,3 mm | *1: When calibrated at both 0% and 30% O2 | Oxygen (O2) | 0...30% | - | - | Voltage | Sensor | +5...+40°C | - | Electrochemical | - mA | ±1% FS *1 | Free wires | Lead-Free, Response time (90%): approx 15 sec. | - |
|
Producent
SGX SENSORTECH
|
- | - | 5 x 7 x 1,5 mm | *1: Heater only | Nitrogen dioxide (NO2) | 50ppb...5ppm | - | - | ΔR | Sensor | -30...+85°C | 1,7V *1 | MOS | 26mA, Typ., *1 mA | - | SMD | - | 1 |
|
Producent
SGX SENSORTECH
|
- | - | 5 x 7 x 1,5 mm | *1: Heater only | Carbon monoxide (CO), Nitrogen dioxide (NO2) | 1...1000ppm CO, 50ppb...5ppm NO2 | - | - | ΔR | Sensor | -30...+85°C | 2,4V: CO, 1,7V: NO2, *1 | MOS | 32mA, Typ.: CO, 26mA, Typ.: NO2, *1 mA | - | SMD | 2 sensing elements, 2 heaters | 1 |
|
Producent
SGX SENSORTECH
|
- | - | 5 x 7 x 1,5 mm | *1: Heater only | Carbon monoxide (CO) | 1...1000ppm | - | - | ΔR | Sensor | -30...+85°C | 2,4V *1 | MOS | 32mA, Typ. *1 mA | - | SMD | - | 1 |
|
Producent
SGX SENSORTECH
|
- | - | 5 x 7 x 1,5 mm | *1: Heater only | Ammonia (NH3) | 1...500ppm | - | - | ΔR | Sensor | -30...+85°C | 2,2V *1 | MOS | 30mA *1 mA | - | SMD | 3 sensing elements, 3 heaters | 1 |
|
Producent
SGX SENSORTECH
|
- | - | 5 x 7 x 1,5 mm | *1: Heater only | Carbon monoxide (CO), Nitrogen dioxide (NO2), Ammonia (NH3) | 1...1000ppm CO, 50ppb...5ppm NO2, 1...500ppm NH3 | - | - | ΔR | Sensor | -30...+85°C | 2,4V: CO, 1,7V: NO2, 2,2V NH3*1 | MOS | 32mA, Typ.: CO, 26mA, Typ.: NO2, 30mA, Typ., *1 mA | - | SMD | - | 1 |
|
Producent
SGX SENSORTECH
|
- | - | 22,9 x 14 x 3,2 mm | - | Volatile organic compound (VOC), CO2_eq | 0...1000ppb isobutylene, 400...2000ppm CO2_eq | - | - | I2C, PWM | Module | 0...+50°C | 3,3V | MOS | 38 mA | - | SMD | - | 1 |
|
Producent
SGX SENSORTECH
|
- | 8mV/% CH4, Min | D14,4 x 6,7 mm | - | Combustible gases | 0...5% CH4 | - | Voltage | ΔR | Sensor | -20...+60°C | 3V | Catalytic | 37...41 mA | - | SMD | ATEX: II 1G Ex da IIC Ga, I M1 Ex da I Ma, UECEx: Ex da IIC | 1 |
|
Producent
NISSHA FIS
|
- | 0,48-0,68 | D13,4 x 7,6 mm | - | Methane (CH4), Iso-butane, Hydrogen (H2) | 100...10 000ppm | - | - | ΔR | Sensor | -20...+50°C | - | MOS | - mA | - | Pins for socket | - | - |
|
Producent
NISSHA FIS
|
- | - | D20 x 10 mm | - | Methane (CH4) | 300...10 000ppm | - | - | ΔR | Sensor | -10...+50°C | - | MOS | - mA | - | Pins for socket | - | - |
|
Producent
NISSHA FIS
|
- | - | D20 x 10 mm | - | Methane (CH4) | 100...5 000ppm | - | - | ΔR | Sensor | -10...+50°C | - | MOS | - mA | - | Pins for socket | - | - |
|
Producent
NISSHA FIS
|
- | 0,55-0,75 | D13,4 x 7,6 mm | - | LPG | 100...10 000ppm | - | - | ΔR | Sensor | -10...+50°C | - | MOS | - mA | - | Pins for socket | - | - |