Notice
You are currently browsing the website for customers from Congo, The Democratic Republic of the. We recommend switching to the United States version of the site, optimized for your region.
|
Manufacturer
SENSIRION
|
- | Module | NDIR | Carbon dioxide (CO2) | 0...40 000ppm at I2C, UART, 0...5 00ppm at PWM | ±(30 ppm + 3%) at 400...10 000ppm | - | UART/I2C, PWM | - | - | 3,3...5,5V | 19 (Avg. Typ.) mA | SMD | 0...+50°C | 35 x 23 x 7 mm | - | RH and T measurement | CO2 output range: 0...40 000ppm I2C, UART, 0...5 000ppm PWM |
|
Manufacturer
SENSIRION
|
SGD4x | Module | Thermal Conductivity | R-32 and R-454B in Air | - | ±2.5 %LFL | - | RS-485/MODBUS | NO contact x2 | 11% LFL (R32), 12% LFL (R-454B) | 24 VDC ±10%, 18...30 VAC RMS | 70 mA Typ. @ DC, 120 mA RMS Typ. @ AC mA | 8-pin sealable connector, mating part TE 794821-1 | -40...+85°C | 90 x 55 x 24 mm | - | Refrigerant sensor: UL 60335-2-40, refrigerant detection: UL 60335-2-89 | LFL: lower flammability limit |
|
Manufacturer
SENSIRION
|
SGD4x | Module | Thermal Conductivity | R-454A, R-454C and R-455A in Air | - | ±2.5 %LFL | - | RS-485/MODBUS | NO contact x2 | 14% LFL (R-454A, C), 10% LFL (R-455A) | 24 VDC ±10%, 18...30 VAC RMS | 70 mA Typ. @ DC, 120 mA RMS Typ. @ AC mA | 8-pin sealable connector, mating part TE 794821-1 | -40...+85°C | 90 x 55 x 24 mm | - | Refrigerant sensor: UL 60335-2-40, refrigerant detection: UL 60335-2-89 | LFL: lower flammability limit |
|
Manufacturer
SENSIRION
|
- | Thermal Conductivity | Thermal Conductivity | CO2 in N2 and CO2 in air | 380...32 000 ppm | ±(100ppm+10% MV) @ 400...5 000 ppm | 1 ppm (Typ.) | I2C | - | - | 2,7...5,5 V | 0,95 mA (Typ., continuous meas. mode) mA | SMD | 10...40°C | 4 x 3 x 1,2 mm | 1 | Automatic Self-Calibration | Requires SHT4x for RH&T compensation |
|
Manufacturer
SENSIRION
|
SCD4x | Sensor | NDIR | Carbon dioxide (CO2) | 0...40 000ppm | ±(50 ppm + 3 %) at 400...2 000ppm | - | I2C | - | - | 2,4...5,5V | 15mA, 3,2mA *1, 0,45mA *2 (Typ., Avg.) @ 3,3V mA | SMD | -10...+60°C | 10,1 x 10,1 x 6,3 mm | 1 | RH and T meas., low power mode, single shot mode | *1: low power mode, *2: single shot mode |
|
Manufacturer
SGX SENSORTECH
|
INIR7 | Module | NDIR | Refrigerants (R290) | 0.02...2,1% | ±6% or ±600pmm *1 | 50 ppm | Modbus RS-485 | Alarm ON: V_supply, Alarm OFF: high impedance | 0,42%, SW configurable | 24 VDC Typ. 4,5...30 VDC | 15 mA @ 24 V mA | Connector | -40...+75°C | Module 67 x 76 x 20,5 mm | - | UL 60335-2-40 / IEC 60079-29-1 / IEC60335-2-40, IP65 | *1: Whichever error is larger, basic error |