Verfügbare filter
Verfügbare filter
|
Hersteller
SGX SENSORTECH
|
- | Module | Thermal Conductivity | H2 in Air | 0...4% | ± 0.4% H2 @ 23°C < 10%RH | - | CAN | - | - | 9...36V | 28mA @24 V mA mA | Connector | -40...+85°C | 39 x 35 x 27 mm | - | IP6K7 | - |
|
Hersteller
SGX SENSORTECH
|
INIR2 | Sensor | NDIR | Carbon dioxide (CO2) | 0...100% | ±6% or ±1500ppm, *1 | ±500ppm @ 5...40% | UART, Voltage 0…2,5V | - | - | 3,2...5,25V | 32mA @ 3,3V, Typ. mA | Pins for socket | -40...+75°C | D20 x 16,6 mm | MSL 1 | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | *1: Whichever error is larger |
|
Hersteller
SGX SENSORTECH
|
INIR2 | Sensor | NDIR | Carbon dioxide (CO2) | 0...5% | ±6% or ±60ppm *1 | ±40ppm @ 0...2% | UART, Voltage 0…2,5V | - | - | 3,2...5,25V | 32mA @ 3,3V, Typ. mA | Pins for socket | -40...+75°C | D20 x 16,6 mm | MSL 1 | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | *1: Whichever error is larger |
|
Hersteller
SGX SENSORTECH
|
INIR2 | Sensor | NDIR | Methane (CH4) | 0...100% | ±6% or 0,06% FS, *1 | - | UART, Voltage 0…2,5V | - | - | 3,2...5,25V | 32mA @ 3,3V, Typ. mA | Pins for socket | -40...+75°C | D20 x 16,6 mm | MSL 1 | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | *1: Whichever error is larger |
|
Hersteller
SGX SENSORTECH
|
INIR2 | Sensor | NDIR | Methane (CH4) | 0...5% | ±6% or 0,06% FS, *1 | - | UART, Voltage 0…2,5V | - | - | 3,2...5,25V | 32mA @ 3,3V, Typ. mA | Pins for socket | -40...+75°C | D20 x 16,6 mm | MSL 1 | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | *1: Whichever error is larger |
|
Hersteller
SGX SENSORTECH
|
INIR2 | Sensor | NDIR | Propane (C3H8) | 0...2,1% | ±6% or 0,06% FS, *1 | - | UART, Voltage 0…2,5V | - | - | 3,2...5,25V | 32mA @ 3,3V, Typ. mA | Pins for socket | -40...+75°C | D20 x 16,6 mm | MSL 1 | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | *1: Whichever error is larger |
|
Hersteller
SGX SENSORTECH
|
INIR7 | Module | NDIR | Refrigerants (R290) | 0.02...2,1% | ±6% or ±600pmm *1 | 50 ppm | CAN 2.0 | Alarm ON: V_supply, Alarm OFF: high impedance | 0,42%, SW configurable | 24 VDC Typ. 4,5...30 VDC | 15 mA @ 24 V mA | Connector | -40...+75°C | Module 67 x 76 x 20,5 mm | - | UL 60335-2-40 / IEC 60079-29-1 / IEC60335-2-40, IP65 | *1: Whichever error is larger, basic error |
|
Hersteller
SGX SENSORTECH
|
- | Sensor | MOS | Nitrogen dioxide (NO2) | 50ppb...5ppm | - | - | ΔR | - | - | 1,7V *1 | 26mA, Typ., *1 mA | SMD | -30...+85°C | 5 x 7 x 1,5 mm | 1 | - | *1: Heater only |
|
Hersteller
SGX SENSORTECH
|
- | Sensor | MOS | Carbon monoxide (CO), Nitrogen dioxide (NO2) | 1...1000ppm CO, 50ppb...5ppm NO2 | - | - | ΔR | - | - | 2,4V: CO, 1,7V: NO2, *1 | 32mA, Typ.: CO, 26mA, Typ.: NO2, *1 mA | SMD | -30...+85°C | 5 x 7 x 1,5 mm | 1 | 2 sensing elements, 2 heaters | *1: Heater only |
|
Hersteller
SGX SENSORTECH
|
- | Sensor | MOS | Carbon monoxide (CO) | 1...1000ppm | - | - | ΔR | - | - | 2,4V *1 | 32mA, Typ. *1 mA | SMD | -30...+85°C | 5 x 7 x 1,5 mm | 1 | - | *1: Heater only |
|
Hersteller
SGX SENSORTECH
|
- | Sensor | MOS | Ammonia (NH3) | 1...500ppm | - | - | ΔR | - | - | 2,2V *1 | 30mA *1 mA | SMD | -30...+85°C | 5 x 7 x 1,5 mm | 1 | 3 sensing elements, 3 heaters | *1: Heater only |
|
Hersteller
SGX SENSORTECH
|
- | Sensor | MOS | Carbon monoxide (CO), Nitrogen dioxide (NO2), Ammonia (NH3) | 1...1000ppm CO, 50ppb...5ppm NO2, 1...500ppm NH3 | - | - | ΔR | - | - | 2,4V: CO, 1,7V: NO2, 2,2V NH3*1 | 32mA, Typ.: CO, 26mA, Typ.: NO2, 30mA, Typ., *1 mA | SMD | -30...+85°C | 5 x 7 x 1,5 mm | 1 | - | *1: Heater only |
|
Hersteller
SGX SENSORTECH
|
- | Module | MOS | Volatile organic compound (VOC), CO2_eq | 0...1000ppb isobutylene, 400...2000ppm CO2_eq | - | - | I2C, PWM | - | - | 3,3V | 38 mA | SMD | 0...+50°C | 22,9 x 14 x 3,2 mm | 1 | - | - |
|
Hersteller
SGX SENSORTECH
|
- | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | 8mV/% CH4, Min | ΔR | Voltage | - | 3V | 37...41 mA | SMD | -20...+60°C | D14,4 x 6,7 mm | 1 | ATEX: II 1G Ex da IIC Ga, I M1 Ex da I Ma, UECEx: Ex da IIC | - |
|
Hersteller
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Oxygen (O2) | 0...25% | - | 4,8 ± 1,4 uA/% O2 | Current | - | - | - | - mA | Pins for socket | -40...+60°C | D20 x 16,5 mm | - | - | Maximum overload: 30% O2 |
|
Hersteller
SGX SENSORTECH
|
- | Module | Thermal Conductivity | H2 in Air | 0...10% | ± 0,4 vol @ H2 in air ≤ 4% vol, H2 in air ≥ 4% vol ± 10% MV | - | CAN | - | - | 9...18V | 25mA @12 V mA | Connector | -40...+85°C | 39 x 35 x 27 mm | - | IP6K7 | - |
|
Hersteller
SGX SENSORTECH
|
- | Module | Thermal Conductivity (H2), MOS (CO) | H2 in air, CO | 0...4% H2 | ± 0,4% @ (Temp 0...25°C, RH 10...95%) | - | CAN | - | - | 9...18V | 50 mA (max.) @ 12V mA | Connector | -40...+85°C | 39 x 35 x 27 mm | - | IP6K7 | - |
|
Hersteller
SGX SENSORTECH
|
- | Sensor | Electrochemical | Oxygen (O2) | 0...100% | - | 0,6 mV/% O2, typ. | Voltage | - | - | - | - mA | Connector | -20...+50°C | D29,3 x 38,2 mm | - | - | Expected operating lifetime: 8,7 years at 21% O2 |
|
Hersteller
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Carbon monoxide (CO) | 0...1000ppm | - | 45 ± 15 nA/ppm | Current | - | - | - | - mA | Pins for socket | -20...+50°C | D20 x 16,5 mm | - | - | - |
|
Hersteller
SGX SENSORTECH
|
- | Module | Thermal Conductivity (H2), MOS (CO, NH3) | - | - | ± 0,4% @ (Temp 0...25°C, RH 10...95%) | - | LIN 2.1 | - | - | 9...15V | 80mA (max) @ 12V mA | Connector | -40...+85°C | 39 x 35 x 27 mm | - | IP6K7, pressure measurement 20...250 kPa over the air pressure | - |
|
Hersteller
SGX SENSORTECH
|
VQ500 | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | 4mV/% CH4, Min. | ΔR | Voltage | - | 4,25V | 50...60 mA | Pins for socket | -40...+55°C | D20 x 16,5 mm | MSL 1 | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | *1: x depends on gas |
|
Hersteller
SGX SENSORTECH
|
VQ500 | Sensor | Catalytic | Ammonia (NH3) | 0...15% | - | 21 mV/% NH3, Min. | ΔR | Voltage | - | 3V | 40...50mA mA | Pins for socket | -40...+55°C | D20 x 16,5 mm | MSL 1 | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | - |
|
Hersteller
SGX SENSORTECH
|
VQ500 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | 30 mV/% CH4, Min. | ΔR | Voltage | - | 4,25V | 50...60 mA | Pins for socket | -40...+55°C | D20 x 16,5 mm | MSL 1 | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | Poison and shock resistant |
|
Hersteller
SGX SENSORTECH
|
- | Accessory | - | - | - | - | - | - | - | - | - | - mA | - | - | - | MSL 1 | - | - |
|
Hersteller
SGX SENSORTECH
|
- | Accessory | - | - | - | - | - | - | - | - | - | - mA | - | - | - | - | - | - |