Fabricant
NISSHA FIS
|
FIS3000 | Module | MOS | Ammonia (NH3) | - | - | - | - | Open collector | 300ppm | 5V | - mA | Connector | -10...+50°C | 31 x 44 x 20 mm | - | SB-53 Sensor, With case, Malfunction output | - |
|
Fabricant
NISSHA FIS
|
FIS3000 | Module | MOS | Ammonia (NH3) | - | - | - | - | CMOS 5V | 300ppm | 5V | - mA | Connector | -10...+50°C | 28 x 41 x 20 mm | - | SB-53 Sensor, Malfunction output | - |
|
Fabricant
NISSHA FIS
|
FIS3000 | Module | MOS | Ammonia (NH3) | - | - | - | UART | Open collector x2 | 100ppm, 300ppm | 5V | - mA | Connector | -10...+50°C | 31 x 44 x 20 mm | - | SB-53 Sensor, With case, Malfunction output | Accuracy of gas concentration output is not guaranteed |
|
Fabricant
NISSHA FIS
|
FIS3000 | Module | MOS | Ammonia (NH3) | - | - | - | UART | CMOS 5V x2 | 100ppm, 300ppm | 5V | - mA | Connector | -10...+50°C | 28 x 41 x 20 mm | - | SB-53 Sensor, Malfunction output | Accuracy of gas concentration output is not guaranteed |
|
Fabricant
NISSHA FIS
|
FIS3000 | Module | MOS | Sulfides | - | - | - | - | Open collector | H2S: 300ppm | 5V | - mA | Connector | -10...+50°C | 31 x 44 x 20 mm | - | SB-51 Sensor, With case, Malfunction output | - |
|
Fabricant
NISSHA FIS
|
FIS3000 | Module | MOS | Sulfides | - | - | - | - | CMOS 5V | H2S: 300ppm | 5V | - mA | Connector | -10...+50°C | 28 x 41 x 20 mm | - | SB-51 Sensor, Malfunction output | - |
|
Fabricant
NISSHA FIS
|
FIS3000 | Module | MOS | Sulfides | - | - | - | UART | Open collector x2 | H2S: 100ppm, 300ppm | 5V | - mA | Connector | -10...+50°C | 31 x 44 x 20 mm | - | SB-51 Sensor, With case, Malfunction output | Accuracy of gas concentration output is not guaranteed |
|
Fabricant
NISSHA FIS
|
FIS3000 | Module | MOS | Sulfides | - | - | - | UART | CMOS 5V x2 | H2S: 100ppm, 300ppm | 5V | - mA | Connector | -10...+50°C | 28 x 41 x 20 mm | - | SB-51 Sensor, Malfunction output | Accuracy of gas concentration output is not guaranteed |
|
Fabricant
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO) | 10...100ppm | - | - | UART | - | - | 3,3V | 18 mA | Connector | -10...+50°C | 28 x 41 x 20 mm | - | SB-AQ9-00 Sensor | - |
|
Fabricant
NISSHA FIS
|
- | Module | NDIR | Carbon dioxide (CO2) | 400...4 000ppm | ±5% | - | PWM | - | - | 5V | 20mA mA | Connector | 0...+40°C | 65 x 20 x 12 mm | - | Dual Beam NDIR | - |
|
Fabricant
NISSHA FIS
|
- | Module | NDIR | Carbon dioxide (CO2) | 400...10 000ppm | - | - | PWM, UART | - | - | 5V | 70 mA | Connector | -20...+70°C | 64 x 23 x 10,7 mm | - | - | - |
|
Fabricant
NISSHA FIS
|
A1320301-SP61 | Module | MOS | Ozone (O3) | 0...1000ppb | - | - | Voltage, 0...5V | CMOS 5V | 700ppb | 5V | 140 mA | Connector, JST S5B-XH-A | 0...+40°C | 51 x 37 x 22 mm | - | SP-61-00 sensor | Accuracy of gas concentration output is not guaranteed |
|
Fabricant
NISSHA FIS
|
FIS5084 | Module | MOS | Refrigerants (R32) | 300...10 000 ppm *1 | Accuracy of gas concentration output is not guaranteed | - | UART | PWM : Duty cycle=60%, f=2,67 Hz | R32: 6 000ppm | 5V | 40 mA | Connector, BH06B-PASK-1 | -25...+60°C | 53 x 30 x 23,5 mm | - | SB-43A Sensor, Malfunction output, with case | *1: If the concentration is > 10,000 ppm, VOUT2 will be permanently locked in alarm state |
|
Fabricant
NISSHA FIS
|
FIS5084 | Module | MOS | Refrigerants (R32) | 300...10 000 ppm *1 | Accuracy of gas concentration output is not guaranteed | - | UART | PWM : Duty cycle=60%, f=2,67 Hz | R32: 5 000ppm ±20% | 5V | 40 mA | Connector, BH06B-PASK-1 | -25...+60°C | 26 x 26 x 20 mm | - | SB-43A Sensor, Malfunction output | *1: If the concentration is > 10,000 ppm, VOUT2 will be permanently locked in alarm state |