Manufacturer
SGX SENSORTECH
|
- | - | 39 x 35 x 27 mm | - | H2 in Air | 0...4% | - | - | CAN | Module | -40...+85°C | 9...36V | Thermal Conductivity | 28mA @24 V mA mA | ± 0.4% H2 @ 23°C < 10%RH | Connector | IP6K7 | - |
|
Manufacturer
SGX SENSORTECH
|
INIR2 | ±500ppm @ 5...40% | D20 x 16,6 mm | *1: Whichever error is larger | Carbon dioxide (CO2) | 0...100% | - | - | UART, Voltage 0…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or ±1500ppm, *1 | Pins for socket | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
INIR2 | ±40ppm @ 0...2% | D20 x 16,6 mm | *1: Whichever error is larger | Carbon dioxide (CO2) | 0...5% | - | - | UART, Voltage 0…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or ±60ppm *1 | Pins for socket | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
INIR2 | - | D20 x 16,6 mm | *1: Whichever error is larger | Methane (CH4) | 0...100% | - | - | UART, Voltage 0…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
INIR2 | - | D20 x 16,6 mm | *1: Whichever error is larger | Methane (CH4) | 0...5% | - | - | UART, Voltage 0…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
INIR2 | - | D20 x 16,6 mm | *1: Whichever error is larger | Propane (C3H8) | 0...2,1% | - | - | UART, Voltage 0…2,5V | Sensor | -40...+75°C | 3,2...5,25V | NDIR | 32mA @ 3,3V, Typ. mA | ±6% or 0,06% FS, *1 | Pins for socket | ATEX: I M2 Ex db I Mb, II 2G Ex db IIC Gb, ICEx: Ex db I Mb, Ex db IIC Gb | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
INIR7 | 50 ppm | Module 67 x 76 x 20,5 mm | *1: Whichever error is larger, basic error | Refrigerants (R290) | 0.02...2,1% | 0,42%, SW configurable | Alarm ON: V_supply, Alarm OFF: high impedance | CAN 2.0 | Module | -40...+75°C | 24 VDC Typ. 4,5...30 VDC | NDIR | 15 mA @ 24 V mA | ±6% or ±600pmm *1 | Connector | UL 60335-2-40 / IEC 60079-29-1 / IEC60335-2-40, IP65 | - |
|
Manufacturer
SGX SENSORTECH
|
- | - | 5 x 7 x 1,5 mm | *1: Heater only | Nitrogen dioxide (NO2) | 50ppb...5ppm | - | - | ΔR | Sensor | -30...+85°C | 1,7V *1 | MOS | 26mA, Typ., *1 mA | - | SMD | - | 1 |
|
Manufacturer
SGX SENSORTECH
|
- | - | 5 x 7 x 1,5 mm | *1: Heater only | Carbon monoxide (CO), Nitrogen dioxide (NO2) | 1...1000ppm CO, 50ppb...5ppm NO2 | - | - | ΔR | Sensor | -30...+85°C | 2,4V: CO, 1,7V: NO2, *1 | MOS | 32mA, Typ.: CO, 26mA, Typ.: NO2, *1 mA | - | SMD | 2 sensing elements, 2 heaters | 1 |
|
Manufacturer
SGX SENSORTECH
|
- | - | 5 x 7 x 1,5 mm | *1: Heater only | Carbon monoxide (CO) | 1...1000ppm | - | - | ΔR | Sensor | -30...+85°C | 2,4V *1 | MOS | 32mA, Typ. *1 mA | - | SMD | - | 1 |
|
Manufacturer
SGX SENSORTECH
|
- | - | 5 x 7 x 1,5 mm | *1: Heater only | Ammonia (NH3) | 1...500ppm | - | - | ΔR | Sensor | -30...+85°C | 2,2V *1 | MOS | 30mA *1 mA | - | SMD | 3 sensing elements, 3 heaters | 1 |
|
Manufacturer
SGX SENSORTECH
|
- | - | 5 x 7 x 1,5 mm | *1: Heater only | Carbon monoxide (CO), Nitrogen dioxide (NO2), Ammonia (NH3) | 1...1000ppm CO, 50ppb...5ppm NO2, 1...500ppm NH3 | - | - | ΔR | Sensor | -30...+85°C | 2,4V: CO, 1,7V: NO2, 2,2V NH3*1 | MOS | 32mA, Typ.: CO, 26mA, Typ.: NO2, 30mA, Typ., *1 mA | - | SMD | - | 1 |
|
Manufacturer
SGX SENSORTECH
|
- | - | 22,9 x 14 x 3,2 mm | - | Volatile organic compound (VOC), CO2_eq | 0...1000ppb isobutylene, 400...2000ppm CO2_eq | - | - | I2C, PWM | Module | 0...+50°C | 3,3V | MOS | 38 mA | - | SMD | - | 1 |
|
Manufacturer
SGX SENSORTECH
|
- | 8mV/% CH4, Min | D14,4 x 6,7 mm | - | Combustible gases | 0...5% CH4 | - | Voltage | ΔR | Sensor | -20...+60°C | 3V | Catalytic | 37...41 mA | - | SMD | ATEX: II 1G Ex da IIC Ga, I M1 Ex da I Ma, UECEx: Ex da IIC | 1 |
|
Manufacturer
SGX SENSORTECH
|
4 series | 4,8 ± 1,4 uA/% O2 | D20 x 16,5 mm | Maximum overload: 30% O2 | Oxygen (O2) | 0...25% | - | - | Current | Sensor | -40...+60°C | - | Electrochemical | - mA | - | Pins for socket | - | - |
|
Manufacturer
SGX SENSORTECH
|
- | - | 39 x 35 x 27 mm | - | H2 in Air | 0...10% | - | - | CAN | Module | -40...+85°C | 9...18V | Thermal Conductivity | 25mA @12 V mA | ± 0,4 vol @ H2 in air ≤ 4% vol, H2 in air ≥ 4% vol ± 10% MV | Connector | IP6K7 | - |
|
Manufacturer
SGX SENSORTECH
|
- | - | 39 x 35 x 27 mm | - | H2 in air, CO | 0...4% H2 | - | - | CAN | Module | -40...+85°C | 9...18V | Thermal Conductivity (H2), MOS (CO) | 50 mA (max.) @ 12V mA | ± 0,4% @ (Temp 0...25°C, RH 10...95%) | Connector | IP6K7 | - |
|
Manufacturer
SGX SENSORTECH
|
- | 0,6 mV/% O2, typ. | D29,3 x 38,2 mm | Expected operating lifetime: 8,7 years at 21% O2 | Oxygen (O2) | 0...100% | - | - | Voltage | Sensor | -20...+50°C | - | Electrochemical | - mA | - | Connector | - | - |
|
Manufacturer
SGX SENSORTECH
|
4 series | 45 ± 15 nA/ppm | D20 x 16,5 mm | - | Carbon monoxide (CO) | 0...1000ppm | - | - | Current | Sensor | -20...+50°C | - | Electrochemical | - mA | - | Pins for socket | - | - |
|
Manufacturer
SGX SENSORTECH
|
- | - | 39 x 35 x 27 mm | - | - | - | - | - | LIN 2.1 | Module | -40...+85°C | 9...15V | Thermal Conductivity (H2), MOS (CO, NH3) | 80mA (max) @ 12V mA | ± 0,4% @ (Temp 0...25°C, RH 10...95%) | Connector | IP6K7, pressure measurement 20...250 kPa over the air pressure | - |
|
Manufacturer
SGX SENSORTECH
|
VQ500 | 4mV/% CH4, Min. | D20 x 16,5 mm | *1: x depends on gas | Mixture of known gas and air | x…100% *1 | - | Voltage | ΔR | Sensor | -40...+55°C | 4,25V | Thermal Conductivity | 50...60 mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
VQ500 | 21 mV/% NH3, Min. | D20 x 16,5 mm | - | Ammonia (NH3) | 0...15% | - | Voltage | ΔR | Sensor | -40...+55°C | 3V | Catalytic | 40...50mA mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
VQ500 | 30 mV/% CH4, Min. | D20 x 16,5 mm | Poison and shock resistant | Combustible gases | 0...5% CH4 | - | Voltage | ΔR | Sensor | -40...+55°C | 4,25V | Catalytic | 50...60 mA | - | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
- | - | - | - | - | - | - | - | - | Accessory | - | - | - | - mA | - | - | - | MSL 1 |
|
Manufacturer
SGX SENSORTECH
|
- | - | - | - | - | - | - | - | - | Accessory | - | - | - | - mA | - | - | - | - |